30D12150P Desktop Power Supply

The 30D12150P Wall mount power supply can be used to power any of the Ethernet Direct Industrial products.
 


Click to Enlarge Image
Quick Download : Data Sheet

Product Specification

 


INPUT
~ AC Input Voltage: 100 - 240V AC
~ AC Input Frequency: 50 / 60 Hz
~ AC Input Current - 230V AC (max): 0.2A
~ AC Inrush Current* - 230V AC, 50Hz: 50A
~ Primary current protection: An internal fuse on the AC input line is provided.
~ Configuration: 3-conductors,

OUTPUT
~ Normal DC Output Voltage: +12.0V
~ Minimum Load Current: 0.0A
~ Maximum Load Current: 1.5A
~ Maximum Output Power: 18W
~ Ripple and Noise: 120mV
~ Over-voltage protection (max): 15.75V DC.
~ Total Output Regulation: +/- 5%
~ Dynamic Load Regulation: +/- 5%
~ Short-circuit protection (max): 5W
~ Efficiency: 65% minimum at normal input voltage and full load.
~ Drop-out: With half cycle input voltage drop-out, the unit shall meet theregulation requirement and operate within the prescribed voltages with a drop-out pulse repetition rate of 500mS under fullload and with normal AC input voltage.
~ Open-circuit protection: When primary power is applied with no load on any output level, nodamage or hazardous conditions should occur.

MECHANICAL
~ Dimensions: 100(L) x 50(W) x 35(H)mm.
~ Weight: 200g
~ Input Plug Type: Desk type, 3-conductors,
~ Output Cord: Wire: SPT-1, VW-1, 18AWG, 1828mm.
~ Output Plug: 10(L) x 5.5(D) x 2.1(ID)mm

ENVIRONMENTAL
~ Operating Temperature: 0ºC to +40ºC
~ Storage Temperature: -20ºC to +60ºC
~ Operating Humidity: 20 ~ 85 % RH. Non-condensing
~ Storage Humidity: 5 ~ 95 % RH. Non-condensing

SAFETY
~ Dielectric withstanding voltage test (Hi-pot test) input to output: 1,800V AC, 10mA, 1 second OR 2,545V DC, 10mA, 1 second.
~ Dielectric withstanding voltage test (Hi-pot test) input to ground: 1,800V AC, 10mA, 1 second OR 2,545V DC, 10mA, 1 second.
~ Insulation Resistance: > 100MΩ at 500V DC between Primary Active, Neutral line andsecondary.
~ Leakage Current: 0.75mA maximum at normal AC input voltage and frequency

RELIABILITY
~ MTBF: 50,000 hours
~ Burn-in Test: 4 hours at 40ºC +/- 5ºC, normal input voltage, 80% of maximum load.

Ordering Information

 
30D12150PPower Supply 90-264 VAC IEC C14 in-line to 12 VDC 1.5A 2.1mmWhere to Buy and Price